MooneyCheck_10 Software
The new Release 10 of the program optimizes the identification of the tests, the management of the instrument and stores the Results in the Gibitre SQL database.



Smart Test Identification 
One of the key characteristics to make an instrument functional is the simplicity in identifying the tests to be carried out.
The new Gibitre release 10 programs allow you to:
• Reduce the time for insertion
• Do not make identification errors
• Identify the correct test procedure for the product
• Have a complete traceability of the archived Results.


Performance of a sequence of tests 
The instrument sequentially executes the list of tests that you have prepared in the ToDoList.
Each test can include test configurations independent of the previous one.
At the end of each test the instrument prepares the required configuration:
• Adjust the test temperature according to the required procedure
• Sets the test time
• Adapts the axes of the graph
• Selects the tolerance limits for the product to be tested.
You just have to insert the specimen and press start.


Management of Test Results 
The results and test curves of all the tests carried out are saved in the Gibitre SQL database and are available through the Datagest program.

Datagest is the Laboratory Information Management System (LIMS) which is always installed in combination with all Gibitre instrument-control programs.
The program is the collector for all the test result produced with the instruments connected and permits to manage the common Archives used by the instruments (Product List, Customer List, Tolerance limits, Order List, etc)




Custom Setups 
The Instrument Configuration page allows you to adapt the operating modes to your needs.
The configurations are saved and applied with each new opening.
The configurations are editable based on the operator access level.


Test Curves 
• The curves relating to the tests carried out are shown in different colors to associate them immediately with the relative results.
• By selecting a result, the corresponding curve is automatically highlighted.
• The graphical functions integrated in the programs (scale settings, the number of divisions and zoom) allow you to analyze the curves in detail.
• All the curves are saved in the database together with the test results.


Option: Variable Rotor Rotation Speed 
Optional configuration of the MooneyCheck-Drive instrument for managing the rotor speed during the test.
• The configuration allows to define the Rotation Speed as a configurable parameter of the Test Procedure.
• The speed can be set between 0.01 and 20 RPM.
• The execution of tests at different speeds allow to evaluate the behavior of your product according to the shear rate and to simulate the behavior of the product in the conditions of use.




Tolerance Limits 
The Datagest program allows you to define specific tolerance limits for each Product, Customer, Test Procedure and Aging Treatment.
For each result to be calculated, tolerance limits and alarm limits can be defined.
The comparison between the results and the tolerance limits is carried out automatically at the end of each test: the test results are colored (Green, Yellow or Red) based on the outcome of the comparison with the limits.
The outcome of the check is saved in the database together with the results.


Statistics of ongoing tests 
The programs automatically process the statistical analysis of the tests in progress by calculating:
• Maximum
• Minimum
• Average
• Median
• Standard deviation
• Cp
• Cpk
In addition, the Gaussian curve relative to the results is shown together with the tolerance limits to immediately highlight the progress of the tests in progress.
The Datagest program allows you to process more detailed statistics related to the saved results and to represent X and R Charts by grouping data by order, batch, batch, date, etc.


Test Procedures 
The SQL database that is installed together with the tools contains predefined test procedures for each type of Gibitre tool.
Test procedures contain:
• settings for automatic instrument adjustment
• the list of results to be calculated on the basis of what is required by international standards.
The Datagest program allows you to: copy, modify, create the Test Procedures to adapt them to your needs.

Test procedures can be exported and imported. This allows Gibitre Remote Support to support you in the preparation and testing of customized Test Procedures.




Language Selection 
All the programs produced by Gibitre are multi-language and allow the operator to select the language of use.
The test report can be produced in the desired language regardless of the language of use of the program.
The languages available at the moment are: Italian, English, German, French, Portuguese, Russian, Chinese, Japanese, Turkish, Polish, Czech


Hardware requirements 
• Programs can be installed on standard PCs with WINDOWS 10 or 11 OPERATING SYSTEM.
• The CONNECTION between the instruments and the PC is made using the USB CABLE supplied with the instrument.
• The programs are COMPATIBLE WITH ANTIVIRUS, and other programs installed on the PC.



Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
The new Release 10 of the program optimizes the identification of the tests, the management of the instrument and stores the Results in the Gibitre SQL database.

MooneyCheck_10 Software

Get a Quotation
The new Release 10 of the program optimizes the identification of the tests, the management of the instrument and stores the Results in the Gibitre SQL database.
Smart Test Identification 
One of the key characteristics to make an instrument functional is the simplicity in identifying the tests to be carried out.
The new Gibitre release 10 programs allow you to:
• Reduce the time for insertion
• Do not make identification errors
• Identify the correct test procedure for the product
• Have a complete traceability of the archived Results.
Performance of a sequence of tests 
The instrument sequentially executes the list of tests that you have prepared in the ToDoList.
Each test can include test configurations independent of the previous one.
At the end of each test the instrument prepares the required configuration:
• Adjust the test temperature according to the required procedure
• Sets the test time
• Adapts the axes of the graph
• Selects the tolerance limits for the product to be tested.
You just have to insert the specimen and press start.
Management of Test Results 
The results and test curves of all the tests carried out are saved in the Gibitre SQL database and are available through the Datagest program.

Datagest is the Laboratory Information Management System (LIMS) which is always installed in combination with all Gibitre instrument-control programs.
The program is the collector for all the test result produced with the instruments connected and permits to manage the common Archives used by the instruments (Product List, Customer List, Tolerance limits, Order List, etc)
 
Custom Setups 
The Instrument Configuration page allows you to adapt the operating modes to your needs.
The configurations are saved and applied with each new opening.
The configurations are editable based on the operator access level.
Test Curves 
• The curves relating to the tests carried out are shown in different colors to associate them immediately with the relative results.
• By selecting a result, the corresponding curve is automatically highlighted.
• The graphical functions integrated in the programs (scale settings, the number of divisions and zoom) allow you to analyze the curves in detail.
• All the curves are saved in the database together with the test results.
Option: Variable Rotor Rotation Speed 
Optional configuration of the MooneyCheck-Drive instrument for managing the rotor speed during the test.
• The configuration allows to define the Rotation Speed as a configurable parameter of the Test Procedure.
• The speed can be set between 0.01 and 20 RPM.
• The execution of tests at different speeds allow to evaluate the behavior of your product according to the shear rate and to simulate the behavior of the product in the conditions of use.
Tolerance Limits 
The Datagest program allows you to define specific tolerance limits for each Product, Customer, Test Procedure and Aging Treatment.
For each result to be calculated, tolerance limits and alarm limits can be defined.
The comparison between the results and the tolerance limits is carried out automatically at the end of each test: the test results are colored (Green, Yellow or Red) based on the outcome of the comparison with the limits.
The outcome of the check is saved in the database together with the results.
Statistics of ongoing tests 
The programs automatically process the statistical analysis of the tests in progress by calculating:
• Maximum
• Minimum
• Average
• Median
• Standard deviation
• Cp
• Cpk
In addition, the Gaussian curve relative to the results is shown together with the tolerance limits to immediately highlight the progress of the tests in progress.
The Datagest program allows you to process more detailed statistics related to the saved results and to represent X and R Charts by grouping data by order, batch, batch, date, etc.
Test Procedures 
The SQL database that is installed together with the tools contains predefined test procedures for each type of Gibitre tool.
Test procedures contain:
• settings for automatic instrument adjustment
• the list of results to be calculated on the basis of what is required by international standards.
The Datagest program allows you to: copy, modify, create the Test Procedures to adapt them to your needs.

Test procedures can be exported and imported. This allows Gibitre Remote Support to support you in the preparation and testing of customized Test Procedures.
Language Selection 
All the programs produced by Gibitre are multi-language and allow the operator to select the language of use.
The test report can be produced in the desired language regardless of the language of use of the program.
The languages available at the moment are: Italian, English, German, French, Portuguese, Russian, Chinese, Japanese, Turkish, Polish, Czech
Hardware requirements 
• Programs can be installed on standard PCs with WINDOWS 10 or 11 OPERATING SYSTEM.
• The CONNECTION between the instruments and the PC is made using the USB CABLE supplied with the instrument.
• The programs are COMPATIBLE WITH ANTIVIRUS, and other programs installed on the PC.
Download
General catalogue

MooneyCheck - Drive
See also   >
MooneyCheck: Risultati Calcolati
See also   >
Datagest Software
See also   >
News
Call to action
Ask for quotation
a guided way to ask
for a quotation
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
Your calls are always welcome
monday to friday
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.