Water Cooling of Press Platens
Controlled cooling devices for platens for molding thermoplastic products



Overview 
The cooling of the surfaces is necessary for the molding of thermoplastic materials because the material must be cooled to the solidification temperature before opening the mold.

The speed with which the mold is cooled influences the characteristics of the final product.

The ISO 293 standard defines the cooling speeds to be used.


Cooling Circuit 
The cooling is performed by means of integrated cooling platens and requires the connection to a water source or a chiller.

Control of Cooling speed 
The molding cycles, which are entered via the press control panel, allow you to define the cooling mode by setting the Final Temperature and the Cooling Gradient.
In this way it is possible to define specific cooling modes based on the solidification temperature and the cooling rate required for the type of product.




Tank for cooling water 
The hot water used for the cooling must be cooled before being discharged.
The optional Thermal-insulated-stainless-steel Tank with 100 l capacity permits the temporary storage of the hot water discharged by the cooling system of Gibitre press.
The water coming from the cooling system is temporarily stored and mixed with the water inside the tank in order to reduce the temperature before being downloaded from the top of the tank with a standard drain hose.
The supply includes the tank, the thermal-insulated pipe for the connection with the press, the pipe for the connection to the water discharge.


Ion Exchange Softener 
The optional softener allows to limit the formation of limestone deposits inside the press cooling system.


Cooling System by Water Circuit (Option) 
Cooling of high efficiency test plates with controlled cooling gradient (between 0 and -50 °C/min) 
Tank for cooling water (Option) 
Tank with a capacity of 100 liters for conditioning the cooling water before draining. The supply includes the thermal-insulated pipe for the connection with the press and the pipe for the connection to the water discharge. 
Ion Exchange Softener (Option)  
Ion exchange softener. The supply includes: 25 liters of strong cationic resin, 50 kg of salt, ball valve for connection to the water mains, hose connector and connection tube. 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
Controlled cooling devices for platens for molding thermoplastic products

Water Cooling of Press Platens

Controlled cooling devices for platens for molding thermoplastic products
Overview 
The cooling of the surfaces is necessary for the molding of thermoplastic materials because the material must be cooled to the solidification temperature before opening the mold.

The speed with which the mold is cooled influences the characteristics of the final product.

The ISO 293 standard defines the cooling speeds to be used.
Cooling Circuit 
The cooling is performed by means of integrated cooling platens and requires the connection to a water source or a chiller.
Control of Cooling speed 
The molding cycles, which are entered via the press control panel, allow you to define the cooling mode by setting the Final Temperature and the Cooling Gradient.
In this way it is possible to define specific cooling modes based on the solidification temperature and the cooling rate required for the type of product.
 
Tank for cooling water 
The hot water used for the cooling must be cooled before being discharged.
The optional Thermal-insulated-stainless-steel Tank with 100 l capacity permits the temporary storage of the hot water discharged by the cooling system of Gibitre press.
The water coming from the cooling system is temporarily stored and mixed with the water inside the tank in order to reduce the temperature before being downloaded from the top of the tank with a standard drain hose.
The supply includes the tank, the thermal-insulated pipe for the connection with the press, the pipe for the connection to the water discharge.
Ion Exchange Softener 
The optional softener allows to limit the formation of limestone deposits inside the press cooling system.
Technical specification
Cooling System by Water Circuit (Option)  Cooling of high efficiency test plates with controlled cooling gradient (between 0 and -50 °C/min)  Tank for cooling water (Option)  Tank with a capacity of 100 liters for conditioning the cooling water before draining. The supply includes the thermal-insulated pipe for the connection with the press and the pipe for the connection to the water discharge.  Ion Exchange Softener (Option)   Ion exchange softener. The supply includes: 25 liters of strong cationic resin, 50 kg of salt, ball valve for connection to the water mains, hose connector and connection tube. 
Download
General catalogue

News
Call to action
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
Your calls are always welcome
monday to friday
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.