MooneyCheck - Drive
Mooney Viscometer controlled by Personal Computer for the performance of Viscosity, Scorch and Stress Relaxation tests


Standards the instrument complies with:   
ASTM D1646;   ASTM D3346;   GOST 10722-76;   ISO 289-1;   ISO 289-2;   ISO 289-4;   JIS K_6300-1;    

 
Gibitre Instruments' Mooney viscometer measures Mooney viscosity, pre-polymerization (scorch), and stress relaxation in polymers and rubber compounds. The test determines the torque required to keep a rotor turning in a cylindrical chamber filled with rubber under controlled pressure, temperature, and speed—the resistance is the Mooney viscosity. It belongs to the suite of laboratory tools for the precise measurement of materials where repeatability is essential.

Why choose it: test chamber and rotor conform to ISO 289-1, ISO 289-2, ISO 289-4 and ASTM D1646, ASTM D3346; precise control via independent temperature controllers (0.1 °C resolution) and a compressed-air cooling circuit to minimize time between measurements; self-calibration with internal weight, pneumatic rotor ejection, touchscreen interface, and status lights for fast, safe operation.

For data management, Mooneycheck supports barcode sample ID and, with Datagest, full management of the Gibitre SQL database.

Options ext

Overview 
The MooneyCheck - Drive is a Mooney Viscometer, which permits to measure the Mooney viscosity, Pre-curing (scorch) and Stress Relaxation Characteristics of uncompounded or compounded rubbers In conformity with ISO 289-1, ISO 289-2, ISO 289-3, ASTM D 1646 Standards.
The test is carried out by measuring the torque, which has to be applied under specified temperature and pressure conditions, in order to rotate a metal disc at 2rpm speed in the cylindrical test chamber filled with rubber.
The resistance offered by the rubber to this rotation is expressed as the Mooney viscosity of the test piece.


Why choose Mooneycheck - Drive? 
• Entirely developed and produced in Italy
• Test chamber and rotor compliant with international standards
• Pneumatic Rotor Ejection
• Primary brand components
• Internal weight for self-calibration of the torque measurement
• Independent thermoregulators with a resolution of 0.1 °C
• Interactive touch-screen display for instrument control
• Optional control of rotor rotation speed
• Easily accessible test chamber with transparent safety panel and safety lock.
• Designed for eventual application of a fume aspiration system.
• Full license of MooneyCheck_10 software optimized for barcode sample identification
• Full license of the Datagest software for the complete management of the Gibitre SQL Standard Database




The new 'Drive' generation 
The new generation of 'Drive' instruments is the result of 40 years of experience in the measurement of rheology of rubber and incorporates the most modern technologies regarding mechanical construction, measurement sensors and control software.

MooneyCheck_10 software 
The MooneyCheck_10 program connects to the Gibitre SQL database to store test Results and Curves within the Datagest data management program.
The program allows you to:
• Quickly identify the sequence of tests to be performed
• Automatically adjust the instrument according to the required test conditions
• Produce the test Curves (Viscosity, Scorch, Stress Relaxation, Temperature)
• Compare the results with the tolerance limits
• Elaborate statistical analysis (Carta-X, Gaussiana, Media, Dev St., Max, Min, Cp, Cpk)
• Produce customized reports


Calculated Results 
The software allows you to prepare customized test procedures that include all the calculations required by the standards and product specifications. The dedicated page describes all the available calculations.



Option: Variable Rotor Rotation Speed 
Optional configuration of the MooneyCheck-Drive instrument for managing the rotor speed during the test.
• The configuration allows to define the Rotation Speed as a configurable parameter of the Test Procedure.
• The speed can be set between 0.01 and 20 RPM.
• The execution of tests at different speeds allow to evaluate the behavior of your product according to the shear rate and to simulate the behavior of the product in the conditions of use.


Instrument control Panel 
The instrument is equipped with a large touch-screen display with dimensions 10.2“.
The buttons on the display permit to start and stop the tests.
The display provides complete information about the status of the instrument: connection to the software, temperature of the dies, diagnostic of the sensors installed.


Rotor Pneumatic Ejection 
All Mooney Viscometers produced by Gibitre have a pneumatic ejection device for the rotor which simplifies the cleaning and replacement of the specimen between subsequent tests.



Light panel 
A light panel, installed in the front part of the instrument, changes the color and permits to check the status of the instrument from a distance.
The indicator light identifies the following statuses: Instrument ready, instrument under test, instrument setting test temperature.


Automatic Torque Calibration 
The Calibration weight integrated with the instrument permits the automatic Calibration of the torque sensor.
The Calibration is easily performed by pressing the Calibration button on the Control Display, which activates the pneumatic lifting of the weight.


Standard Calibration service for Mooney Viscometer 
The calibration is performed with reference to the requirements of ISO 289-1 standard.
The service includes:
• Ordinary maintenance of the instrument
• Replacement of the sealing of the lower die.
• Calibration of the temperature of upper and lower dies of instrument (at 100°C and 125°C).
• Calibration of the time for temperature recovery at test start
• Calibration of the torque reading (at 100 Mooney points)
• Calibration of the rotation speed of the rotor
• Final check with Standard Gibitre Compound
• Issue and e-mail shipment of the Calibration Certificate with traceability to primary standards.




Certified Rubber Samples For Mooney Test 
Pair of certified butyl rubber specimens (Isobutylene - Isoprene) for the verification of Mooney Viscosity.

The specimens are obtained, without rework, from a bale coded as IRM (Industry Reference Material) prepared by the working group ASTM D11.20 (task Group subcommittee on Compounding Materials and Procedures) in accordance with ASTM D 4678.


Datagest program : total Traceability 
The Datagest program is the Database Management Tool always installed in combination with all Gibitre instrument-control programs.
The program permits to:
• Select, filter, print, export and analyse the test results stored with all the instruments connected.
• Prepare test procedures by defining the test conditions and the results to be produced
• Set tolerance limits for each product by manual insertion or using the statistical analysis (mean and standard deviation) of saved results
• Prepare multi-instrument test reports


Gibitre Standard SQL Database 
All the Gibitre programs use a database with SQL structure for saving the results.
The database can be installed inside an SQL instance present on the company server or it can be installed on a PC connected to a measuring instrument. The installation of the Microsoft SQL service (Express version) is included in the delivery.




Industry 4.0 integration 
The instrument and the software have been specifically developed to optimize integration with other environments.
The database in SQL format and the Gibitre_Company_Connect program allows you synchronize your company management software with Gibitre database and to speed up the identification of the tests and to use bar-code readers or similar devices.


Preparation of Test Reports 
Version 10 programs make the following options available for preparing test reports:
• Selection of printing language
• Company logo insertion
• Print a single test / a Group of tests
• Print of Test Curves
• Print Numerical Results
• Print the Limits of Tolerance
• Print Statistical Results
• Print Legend with explanation of results
• Print the Operator Signature
• Print Customized Notes
• Preparation of PDF file

The program integrates a REPORT EDITOR that allows you to completely edit the report and prepare fully customized report formats.


Temperature regulation 
The temperature can be set between room temperature and 250°C.
The regulation of the temperature is performed using thermo-regulators with PID micro-processor and with 0.1°C resolution.
Independent temperature control units ensure sophisticate temperature control and easy replacement in case of failure.
Electrical heating resistances have been specifically designed for this instrument to ensure quick and efficient heating.




Safety devices 
The instrument is equipped with:
• Class 1 Safety switch, which prevents the closure of the dies if the safety panel is not closed.
• Safety Push-button
• Safety lock of the maintenance access door, which ensures safe usage even in non-standard operation conditions.
• CE Labelling


Easy cleaning of the instrument 
The instrument has been specifically developed for easy cleaning of the test chamber. Technical improvements are:
• Seal design to prevent the flowing of rubber below the rotor
• Easy rotor removing by pneumatic ejection
• The shaft housing hole is open from top to bottom to permit easy cleaning.
• The cleaning activity does not require regulation of rotor height


Development and production 
The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.




 

Film Foils for Mooney Tests 
Polyamide or Polyester Film for the protection of the dies during the test.

Volumetric cutter 
Volumetric cutter for the preparation of test Samples with Constant Volume


Instrument Characteristics 
 
Type of tests performed 
Viscosity, Scorch, Stress Relaxation 
Torque sensor 
Capacity: 230 MU
Resolution: 0.01 MU
Linearity Error (%FS): +-0.25 
Temperature 
Between room temperature and +250 °C - Resolution 0.1 °C 
Frequency of rotation 
Standard Instrument: 2.00 r/min ± 0.02 r/min (0,209 rad/s ± 0,002 rad/s)
With variable speed option: adjustable between 0.01 to 20 r/min ± 1 % 
Software 
 
Numerical test data  
Viscosity test: MU_ini, t_ini, MU_min, t_min, Dt_MU, MU_4, MU_X, Dt(X-Y), S4, SX (X,Y=customer def.)
Scorch test: ts5, ts35, Dt_35-5, ts3, ts18, Dt_18-3, tsX, Dt_X-Y
Stress relaxation test: a, k, r, A, TX%  
Units 
Torque: Mooney Point (MU)
Time: minutes and seconds, minutes and minutes/100, seconds
Temperature: °C, °F 
Test curves 
Torque versus time curve, Log Mooney versus Log time of Stress Relaxation test, Upper and Lower Test Chamber temperatures 
Software 
 
Results storage 
The test result sand the curves are stored in the SQL Gibitre database which is installed in combination with the software 
Software usage Languages 
Italian, English, French, Spanish, German, Portuguese, Russian, Chinese, Japanese, Turkish, Polish, Czech 
Control Panel 
 
Data displayed 
Active connection to the software, motor on-off, temperatures of the dies, heating status, test running 


Type of device 
Capacitive-Touch-Screen display (permits the use with gloves) 
Characteristics 
Dimensions 10.2” 
Light Panel 
 
Permits to check from a distance the following statuses 
Instrument ready, instrument under test, instrument setting test temperature 
Safety Devices 
 
Safety Devices 
Class 1 Safety switch for main piston (Idem)
Safety Pushbutton
Safety lock of the maintenance access door
CE labelling 
Labelling 
CE Labelling 
Calibration 
 
Automatic Calibration system 
Calibration weight integrated with the instrument with pleumatic lifting system for automatic torque calibration 
Calibration Report 
Calibration report with traceability to primary standards in conformity with the Calibration requirements specified in ISO 289-1 standard 
Construction Characteristics 
 
Electronic Card 
Electronic card with STN 32F 429 micro-processor 
Power supply 
220 VAC ± 10%, 50-60 Hz ± 3, 4 A, single phase
110 VAC ± 10%, 60 Hz ± 3 on request 
Electrical power 
1100 Watt 
Compressed air 
6 bar 
Dimensions of instrument 
(Width x Depth x Height) 684 x 671 x 1419 mm 
Weight 
180 Kg 
Personal Computer (optional) 
 
Personal Computer (optional) 
Minimum Configuration: Intel Core i5 4 GB RAM.
Compatible Operating Systems: Windows 10 and 11;
Connection to the instrument via USB Cable (included) 
Options 
 
Volumetric Die Cutter 
For the preparation of samples with constant volume 
Film for testing 
 
Boxes with film foils 
Thickness: 0.023 mm
Dimension: 100 x 100 mm
Box Content: 500 foils
The boxex are supplied in couples. One box contains 500 standard foils. The other contains 500 foils with central hole for rotor insertion 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
Mooney Viscometer controlled by Personal Computer for the performance of Viscosity, Scorch and Stress Relaxation tests
Campi di applicazione  >  Prove su pneumatici  >  Rheocheck MD - Drive
MooneyCheck - Drive
viscometer mooney drive: Viscosimètre Mooney-Check modèle Drive pour les essais de viscosité conformément aux normes ISO 289, ASTM D1646 et ASTM D3346. Vue complète de l'instrument.
Get a Quotation

Mooney Viscometer controlled by Personal Computer for the performance of Viscosity, Scorch and Stress Relaxation tests

Applications

Gibitre Instruments' Mooney viscometer measures Mooney viscosity, pre-polymerization (scorch), and stress relaxation in polymers and rubber compounds. The test determines the torque required to keep a rotor turning in a cylindrical chamber filled with rubber under controlled pressure, temperature, and speed—the resistance is the Mooney viscosity. It belongs to the suite of laboratory tools for the precise measurement of materials where repeatability is essential.

Why choose it: test chamber and rotor conform to ISO 289-1, ISO 289-2, ISO 289-4 and ASTM D1646, ASTM D3346; precise control via independent temperature controllers (0.1 °C resolution) and a compressed-air cooling circuit to minimize time between measurements; self-calibration with internal weight, pneumatic rotor ejection, touchscreen interface, and status lights for fast, safe operation.

For data management, Mooneycheck supports barcode sample ID and, with Datagest, full management of the Gibitre SQL database.

Options ext
Pourquoi choisir MooneyCheck - Drive ?

Overview 

The MooneyCheck - Drive is a Mooney Viscometer, which permits to measure the Mooney viscosity, Pre-curing (scorch) and Stress Relaxation Characteristics of uncompounded or compounded rubbers In conformity with ISO 289-1, ISO 289-2, ISO 289-3, ASTM D 1646 Standards.
The test is carried out by measuring the torque, which has to be applied under specified temperature and pressure conditions, in order to rotate a metal disc at 2rpm speed in the cylindrical test chamber filled with rubber.
The resistance offered by the rubber to this rotation is expressed as the Mooney viscosity of the test piece.

viscometer mooney drive: Viscomètre Mooney. Vue détaillée du rotor conforme aux normes ISO ISO 289, ASTM D1646, ASTM D3346. viscometer mooney drive: Viscomètre Mooney. Vue détaillée du rotor conforme aux normes ISO ISO 289, ASTM D1646, ASTM D3346. viscometer mooney drive: vérification de la température de la chambre d'essai à l'aide d'une caméra thermique

Why choose Mooneycheck - Drive? 

• Entirely developed and produced in Italy
• Test chamber and rotor compliant with international standards
• Pneumatic Rotor Ejection
• Primary brand components
• Internal weight for self-calibration of the torque measurement
• Independent thermoregulators with a resolution of 0.1 °C
• Interactive touch-screen display for instrument control
• Optional control of rotor rotation speed
• Easily accessible test chamber with transparent safety panel and safety lock.
• Designed for eventual application of a fume aspiration system.
• Full license of MooneyCheck_10 software optimized for barcode sample identification
• Full license of the Datagest software for the complete management of the Gibitre SQL Standard Database

viscometer mooney drive: Fabriqué avec soin en Italie pour une plus grande durabilité
Fabriqué avec soin en Italie pour une plus grande durabilité

The new 'Drive' generation 

The new generation of 'Drive' instruments is the result of 40 years of experience in the measurement of rheology of rubber and incorporates the most modern technologies regarding mechanical construction, measurement sensors and control software.

viscometer mooney drive: Logo des modèles d'instruments en version Drive.
Logo des modèles d'instruments en version Drive.
viscometer mooney drive: Logiciel Mooney-Check version 10. Page principale du logiciel avec courbes d'essai superposées, résultats numériques et statistiques.
 
Logiciel

MooneyCheck_10 software 

The MooneyCheck_10 program connects to the Gibitre SQL database to store test Results and Curves within the Datagest data management program.
The program allows you to:
• Quickly identify the sequence of tests to be performed
• Automatically adjust the instrument according to the required test conditions
• Produce the test Curves (Viscosity, Scorch, Stress Relaxation, Temperature)
• Compare the results with the tolerance limits
• Elaborate statistical analysis (Carta-X, Gaussiana, Media, Dev St., Max, Min, Cp, Cpk)
• Produce customized reports

viscometer mooney drive: Logiciel Mooney-Check version 10. Page principale du logiciel avec courbes d'essai superposées, résultats numériques et statistiques.
Logiciel Mooney-Check version 10. Page principale du logiciel avec courbes d'essai superposées, résultats numériques et statistiques.

Calculated Results 

The software allows you to prepare customized test procedures that include all the calculations required by the standards and product specifications. The dedicated page describes all the available calculations.

viscometer mooney drive: Logiciel Gibitre. Formules de calcul des résultats. Logiciel Mooney-Check. Calcul du Delta-Mooney : changement de la valeur de la viscosité entre les temps t1 et t2. viscometer mooney drive: Logiciel Gibitre. Formules de calcul des résultats. Logiciel Mooney-Check. Calcul du Delta-Mooney : changement de la valeur de la viscosité entre les temps t1 et t2. viscometer mooney drive: Logiciel Gibitre. Formules de calcul des résultats. Mooney-Check. Formule de calcul de la droite de régression du test de relaxation. Représentation en diagramme bilogarithmique. viscometer mooney drive: Logiciel Gibitre. Formules de calcul des résultats. Logiciel Mooney-Check. Test Scorch. Calcul du Delta_ts : temps nécessaire à l'augmentation de la viscosité entre 5 et 35 MU.

Option: Variable Rotor Rotation Speed 

Optional configuration of the MooneyCheck-Drive instrument for managing the rotor speed during the test.
• The configuration allows to define the Rotation Speed as a configurable parameter of the Test Procedure.
The speed can be set between 0.01 and 20 RPM.
• The execution of tests at different speeds allow to evaluate the behavior of your product according to the shear rate and to simulate the behavior of the product in the conditions of use.

viscometer mooney drive: Logiciel Gibitre. Programme Mooney-Check pour le contrôle du viscosimètre Mooney. Liste d'essais avec différentes vitesses de rotation du rotor. viscometer mooney drive: Logiciel Gibitre. Programme Mooney-Check pour le contrôle du viscosimètre Mooney. Liste d'essais avec différentes vitesses de rotation du rotor. viscometer mooney drive: Logiciel Gibitre. Rapports d'essais personnalisables. Les rapports permettent d'identifier les tests avec différentes couleurs pour reconnaître la courbe de test correspondante. viscometer mooney drive: Viscosimètre Mooney : vitesse du rotor réglable.
viscometer mooney drive: Panneau de commande à écran tactile
Développé pour l'utilisateur

Instrument control Panel 

The instrument is equipped with a large touch-screen display with dimensions 10.2“.
The buttons on the display permit to start and stop the tests.
The display provides complete information about the status of the instrument: connection to the software, temperature of the dies, diagnostic of the sensors installed.

viscometer mooney drive: Écran tactile : tout au bout des doigts viscometer mooney drive: Écran tactile : tout au bout des doigts viscometer mooney drive: Mooney-Check-Drive : écran tactile pour le contrôle des instruments.

Rotor Pneumatic Ejection 

All Mooney Viscometers produced by Gibitre have a pneumatic ejection device for the rotor which simplifies the cleaning and replacement of the specimen between subsequent tests.

viscometer mooney drive: Détail de l'éjection pneumatique du rotor viscometer mooney drive: Détail de l'éjection pneumatique du rotor viscometer mooney drive: Détail de l'éjection pneumatique du rotor viscometer mooney drive: Détail de l'éjection pneumatique du rotor

Light panel 

A light panel, installed in the front part of the instrument, changes the color and permits to check the status of the instrument from a distance.
The indicator light identifies the following statuses: Instrument ready, instrument under test, instrument setting test temperature.

viscometer mooney drive: Vérifier l'état de l'instrument à distance viscometer mooney drive: Vérifier l'état de l'instrument à distance viscometer mooney drive: Presse de laboratoire : Vue de face du panneau lumineux d'indication de l'état de fonctionnement.
viscometer mooney drive: Séquence d'éjection pneumatique du rotor
Calibrage

Automatic Torque Calibration 

The Calibration weight integrated with the instrument permits the automatic Calibration of the torque sensor.
The Calibration is easily performed by pressing the Calibration button on the Control Display, which activates the pneumatic lifting of the weight.

viscometer mooney drive: Etalonnage automatique du couple
Etalonnage automatique du couple

Standard Calibration service for Mooney Viscometer 

The calibration is performed with reference to the requirements of ISO 289-1 standard.
The service includes:
• Ordinary maintenance of the instrument
• Replacement of the sealing of the lower die.
• Calibration of the temperature of upper and lower dies of instrument (at 100°C and 125°C).
• Calibration of the time for temperature recovery at test start
• Calibration of the torque reading (at 100 Mooney points)
• Calibration of the rotation speed of the rotor
• Final check with Standard Gibitre Compound
• Issue and e-mail shipment of the Calibration Certificate with traceability to primary standards.

Sample Calibration Report
viscometer mooney drive: Étalonnage de Gibitre : conformité totale avec les normes
Étalonnage de Gibitre : conformité totale avec les normes

Certified Rubber Samples For Mooney Test 

Pair of certified butyl rubber specimens (Isobutylene - Isoprene) for the verification of Mooney Viscosity.

The specimens are obtained, without rework, from a bale coded as IRM (Industry Reference Material) prepared by the working group ASTM D11.20 (task Group subcommittee on Compounding Materials and Procedures) in accordance with ASTM D 4678.

viscometer mooney drive: Éprouvettes certifiées pour les tests de viscosité mooney. Emballage contenant une paire d'éprouvettes sous vide et une étiquette d'identification. viscometer mooney drive: Éprouvettes certifiées pour les tests de viscosité mooney. Emballage contenant une paire d'éprouvettes sous vide et une étiquette d'identification. viscometer mooney drive: Échantillons certifiés pour la vérification de l'étalonnage du viscosimètre Mooney. Certificat d'étalonnage pour une balle codée comme IRM (Industry Reference Material) préparé par le sous-comité ASTM D11.20 Task Group on Compounding Materials and P
viscometer mooney drive: Logiciel Datagest version 10 pour la gestion des résultats archivés. Détail de la page de sélection des résultats avec aperçu du rapport de test.
Data Management

Datagest program : total Traceability 

The Datagest program is the Database Management Tool always installed in combination with all Gibitre instrument-control programs.
The program permits to:
Select, filter, print, export and analyse the test results stored with all the instruments connected.
Prepare test procedures by defining the test conditions and the results to be produced
Set tolerance limits for each product by manual insertion or using the statistical analysis (mean and standard deviation) of saved results
Prepare multi-instrument test reports

viscometer mooney drive: Gestion unique de tous les résultats
Gestion unique de tous les résultats

Gibitre Standard SQL Database 

All the Gibitre programs use a database with SQL structure for saving the results.
The database can be installed inside an SQL instance present on the company server or it can be installed on a PC connected to a measuring instrument. The installation of the Microsoft SQL service (Express version) is included in the delivery.

viscometer mooney drive: SQL : une sécurité totale pour vos données
SQL : une sécurité totale pour vos données

Industry 4.0 integration 

The instrument and the software have been specifically developed to optimize integration with other environments.
The database in SQL format and the Gibitre_Company_Connect program allows you synchronize your company management software with Gibitre database and to speed up the identification of the tests and to use bar-code readers or similar devices.

viscometer mooney drive: Intégration des logiciels de gestion et de laboratoire
Intégration des logiciels de gestion et de laboratoire

Preparation of Test Reports 

Version 10 programs make the following options available for preparing test reports:
• Selection of printing language
• Company logo insertion
• Print a single test / a Group of tests
• Print of Test Curves
• Print Numerical Results
• Print the Limits of Tolerance
• Print Statistical Results
• Print Legend with explanation of results
• Print the Operator Signature
• Print Customized Notes
• Preparation of PDF file

The program integrates a REPORT EDITOR that allows you to completely edit the report and prepare fully customized report formats.

viscometer mooney drive: Rapport de test : votre carte de visite viscometer mooney drive: Rapport de test : votre carte de visite viscometer mooney drive: Programmes Gibitre. Le logiciel de l'instrument permet de préparer des rapports d'essai personnalisés avec les résultats des essais effectués. Page de sélection du modèle de rapport et de la langue d'impression. viscometer mooney drive: Préparer vos formats de rapports personnalisés

Temperature regulation 

The temperature can be set between room temperature and 250°C.
The regulation of the temperature is performed using thermo-regulators with PID micro-processor and with 0.1°C resolution.
Independent temperature control units ensure sophisticate temperature control and easy replacement in case of failure.
Electrical heating resistances have been specifically designed for this instrument to ensure quick and efficient heating.

viscometer mooney drive: Logiciel du viscosimètre Mooney-Check. Détail de l'enregistrement de la température de la chambre pendant un essai.
Logiciel du viscosimètre Mooney-Check. Détail de l'enregistrement de la température de la chambre pendant un essai.

Safety devices 

The instrument is equipped with:
Class 1 Safety switch, which prevents the closure of the dies if the safety panel is not closed.
• Safety Push-button
Safety lock of the maintenance access door, which ensures safe usage even in non-standard operation conditions.
CE Labelling

viscometer mooney drive: La sécurité avant tout
La sécurité avant tout

Easy cleaning of the instrument 

The instrument has been specifically developed for easy cleaning of the test chamber. Technical improvements are:
• Seal design to prevent the flowing of rubber below the rotor
• Easy rotor removing by pneumatic ejection
• The shaft housing hole is open from top to bottom to permit easy cleaning.
• The cleaning activity does not require regulation of rotor height

viscometer mooney drive: Séquence de démontage rapide de la chambre pour le nettoyage - phase 1 viscometer mooney drive: Séquence de démontage rapide de la chambre pour le nettoyage - phase 1 viscometer mooney drive: Séquence de démontage rapide de la chambre pour le nettoyage - phase 2 viscometer mooney drive: Séquence de démontage rapide de la chambre pour le nettoyage - étape 3

Development and production 

The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.

viscometer mooney drive: Fièrement fabriqué en Italie
Fièrement fabriqué en Italie

 

Accessories

Film Foils for Mooney Tests 

Polyamide or Polyester Film for the protection of the dies during the test.

viscometer mooney drive: Échantillons à volume constant = Plus grande répétabilité viscometer mooney drive: Échantillons à volume constant = Plus grande répétabilité viscometer mooney drive: Test de viscosité Mooney. Préparation de l'essai. Les deux échantillons montés au-dessus et au-dessous du rotor avec leurs feuilles de protection de la chambre.

Volumetric cutter 

Volumetric cutter for the preparation of test Samples with Constant Volume

viscometer mooney drive: Échantillons à volume constant = Plus grande répétabilité
Échantillons à volume constant = Plus grande répétabilité

Technical specification

Reference Standards
Standards the instrument complies with:  ISO 289-1; ISO 289-2; ISO 289-4; ASTM D1646; ASTM D3346; GOST 10722-76; JIS K_6300-1;  

Instrument Characteristics

Type of tests performed  Viscosity, Scorch, Stress Relaxation  Torque sensor  Capacity: 230 MU
Resolution: 0.01 MU
Linearity Error (%FS): +-0.25 
Temperature  Between room temperature and +250 °C - Resolution 0.1 °C  Frequency of rotation  Standard Instrument: 2.00 r/min ± 0.02 r/min (0,209 rad/s ± 0,002 rad/s)
With variable speed option: adjustable between 0.01 to 20 r/min ± 1 % 

Software

Numerical test data   Viscosity test: MU_ini, t_ini, MU_min, t_min, Dt_MU, MU_4, MU_X, Dt(X-Y), S4, SX (X,Y=customer def.)
Scorch test: ts5, ts35, Dt_35-5, ts3, ts18, Dt_18-3, tsX, Dt_X-Y
Stress relaxation test: a, k, r, A, TX%  
Units  Torque: Mooney Point (MU)
Time: minutes and seconds, minutes and minutes/100, seconds
Temperature: °C, °F 
Test curves  Torque versus time curve, Log Mooney versus Log time of Stress Relaxation test, Upper and Lower Test Chamber temperatures 

Software

Results storage  The test result sand the curves are stored in the SQL Gibitre database which is installed in combination with the software  Software usage Languages  Italian, English, French, Spanish, German, Portuguese, Russian, Chinese, Japanese, Turkish, Polish, Czech 

Control Panel

Data displayed  Active connection to the software, motor on-off, temperatures of the dies, heating status, test running  Type of device  Capacitive-Touch-Screen display (permits the use with gloves)  Characteristics  Dimensions 10.2” 

Light Panel

Permits to check from a distance the following statuses  Instrument ready, instrument under test, instrument setting test temperature 

Safety Devices

Safety Devices  Class 1 Safety switch for main piston (Idem)
Safety Pushbutton
Safety lock of the maintenance access door
CE labelling 
Labelling  CE Labelling 

Calibration

Automatic Calibration system  Calibration weight integrated with the instrument with pleumatic lifting system for automatic torque calibration  Calibration Report  Calibration report with traceability to primary standards in conformity with the Calibration requirements specified in ISO 289-1 standard 

Construction Characteristics

Electronic Card  Electronic card with STN 32F 429 micro-processor  Power supply  220 VAC ± 10%, 50-60 Hz ± 3, 4 A, single phase
110 VAC ± 10%, 60 Hz ± 3 on request 
Electrical power  1100 Watt  Compressed air  6 bar  Dimensions of instrument  (Width x Depth x Height) 684 x 671 x 1419 mm  Weight  180 Kg 

Personal Computer (optional)

Personal Computer (optional)  Minimum Configuration: Intel Core i5 4 GB RAM.
Compatible Operating Systems: Windows 10 and 11;
Connection to the instrument via USB Cable (included) 

Options

Volumetric Die Cutter  For the preparation of samples with constant volume 

Film for testing

Boxes with film foils  Thickness: 0.023 mm
Dimension: 100 x 100 mm
Box Content: 500 foils
The boxex are supplied in couples. One box contains 500 standard foils. The other contains 500 foils with central hole for rotor insertion 
References
Gibitre Mooney Check
is currently installed in
35 countries
Request the List of top References
Download
Extended product brochure   
Brief product leaflet
General catalogue mail request

Calibration certificate
example
CE certificate
example
RheoCheck MD - Drive
Vedi anche: Reometro Rheocheck MD
See Also   >
Constant Volume Sample Cutter - Mooney
Vedi anche: Volumetric-Die-Cutter-Drive : vue complète de la découpeuse volumétrique Mooney pour Viscometer.
See Also   >
Certified Samples for Mooney Test
Vedi anche: Éprouvettes certifiées pour les tests de viscosité mooney. Emballage contenant une paire d'éprouvettes sous vide et une étiquette d'identification.
See Also   >
News
Call to action
Ask for quotation
a guided way to ask
for a quotation
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
We welcome your calls Monday through Friday from 8:30 a.m. to 5:30 p.m. in your local time zone.
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Gibitre Instruments S.r.l., Via dell'industria 73, 24126 Bergamo Italia, pec@gibitre-instruments.it P. IVA: IT02827900164 CCIAA REA Bergamo: 326486 | ©2018 - 2026 Gibitre Instruments
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.