Block Oven Aging Check
Thermal regulated Block for the performance of ageing tests in air and in liquids of elastomeric materials at temperatures up to 250°C


Standards the instrument complies with:   
ASTM D471;   ASTM D543;   ASTM D865;   ASTM D1056;   AS_NZS 4179;   EN 681-1;   ISO 175;   ISO 188;   ISO 1817;   ISO 12046;   ISO 6916-1;   ISO 6916-2;   VDA 675-301;    

 
The Gibitre Thermoregulated Block accelerates aging of elastomeric materials in air or liquids up to 250 °C, enabling laboratory measurement to ISO 188, ISO 1817, ASTM D865 and ASTM D471.

Four independent stations allow parallel testing of different materials, reducing cycle time and enabling direct comparison.

Temperature is regulated by a PT100 probe with PID control, integrated timer and automatic heater shutoff for stable, repeatable aging.

A thermally insulated stainless-steel housing and an aluminum block with calibrated wells for glass tubes, plus an over-temperature safety switch, ensure safety and long-term reliability.

An external rack simplifies sample preparation and handling; accessories include 38 mm × 300 mm glass test tubes and water-cooled reflux condensers for liquid aging.

CE-marked, the Gibitre Thermoregulated Block is a robust addition to laboratory testing tools for elastomer measurement, delivering consistent, standards-compliant results.

Overview 
Thermal regulated Block for the performance of aging tests in air and in liquids of elastomeric materials at temperatures up to 250°C conforming to ISO 188, 1817 ASTM D 471 and 865 Standards.
Aging tests are typically carried out to measure the variation of characteristics of an article before and after the aging process. The characteristics that are most frequently measured before and after aging are:
• Variation of mechanical characteristics (loading, lengthening, tearing)
• Variation of hardness
• Percentage variation of mass and volume.
Gibitre, in addition to providing this tool to perform accelerated aging in air or in liquid, also provides the tools to measure changes in the properties of the article and to produce the related reports.

Instruments Characteristics  
The instrument is fitted with:
• Aluminium block contained in a stainless steel housing with thermal insulation with 4 calibrated holes designed for the insertion of 4 glass test tubes
• Heating resistance
• PT 100 thermal probe for temperature measurement
• PID thermoregulator
• Timer for the set of the heating time with automatic switch off of the heater at the end of the set time




Timer for Auto-Stop 
The instrument is equipped with a timer that can be set between 0 and 99 hours and 59 minutes. The instrument automatically stops at the end of the set test time.
The Timer allows you to activate aging cycles by ending the test automatically in the absence of the operator.


Glass Tubes for samples. 
4 glass tubes with a diameter of 38 mm and a length of 300 mm can be inserted into the instrument.
The specimens can be inserted into the glass tubes and locked using the fasteners provided.
Fixing devices allow the specimens to be placed in order to avoid contact with the glass tube walls.


Glass Tubes for test according to ASTM D865 
The glass tubes are closed in the upper part with PTFE plugs provided with holes for the insertion of the glass pipes requested for the aging test in hot air according to ASTM D865



Water-cooled reflux condenser 
For aging tests in volatile liquids it is necessary to use condensation columns connected to a water supply. The condensation columns allow to condense the volatile part of the test liquid and make it fall back into the tube. In this way, the amount and formulation of the liquid in the glasses will remain unchanged.
A condensation column can be applied to each test tube.


Removable Side Supports 
Together with the instrument are supplied two side supports for housing the glass tubes not in use. The supports can be removed to reduce the overall dimensions of the instrument.

Safety Devices 
• Safety switch to prevent overheating
• Safety Push-button
• CE Labelling




Standard Calibration service for a Block Oven 
The calibration is performed with reference to the requirements of ISO 1817 standard.
The service includes:
• Ordinary maintenance of the instrument
• Calibration of the temperature inside the testing tubes (at 70°C, 150°C, 200°C, 250°C).
• Issue and e-mail shipment of the Calibration Certificate with traceability to primary standards.


Development and production 
The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.



Testing Configuration 
 
Test stations 
4 glass tubes with a diameter of 38 mm and a length of 300 mm. Each tube can hold up to 6 samples (ISO 37 S2 type). 
Condensation Columns 
A condensation column cooled with running water can be applied to each test tube to prevent evaporation of the test liquid. 
Heating system 
The thermal resistance surrounding the round-shaped aluminium block ensures uniform heating of the system 
Temperature control range 
From room temperature to 250°C (Resolution 1 °C) 
Timer for set of test time 
Timer with hour and minute settings and automatic heating shut-off at the end of the set time. Set time: from 1 min to 700,000 h 
Safety Devices 
 
Safety devices 
Safety Pushbutton.
safety thermostat for over-heating 
Labelling 
CE Labelling 
Calibration 
 
Calibration 
Calibration Report conforming to ISO 1817 with traceability to primary standards 
Technical specifications 
 
Power supply 
220 VAC ±10%, 50 Hz ±3, 10A, single phase - 110 VAC ±10%, 60 Hz ±3 on request. 
Electrical power 
1.5 kW 


Dimensions 
Instrument only: 400 x 420 x 360 mm
With test tubes holders: 490 x 420 x 360 mm
And with reflux condenser mounted: 490 x 420 x 860 mm 
Weight 
24 Kg 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
Thermal regulated Block for the performance of ageing tests in air and in liquids of elastomeric materials at temperatures up to 250°C
Campi di applicazione  >  Prove su pneumatici  >  Rheocheck MD - Drive
Block Oven Aging Check
block oven for aging: Thermoregulated block for accelerated aging tests according to ISO 1817 and ASTM D471
Get a Quotation

Thermal regulated Block for the performance of ageing tests in air and in liquids of elastomeric materials at temperatures up to 250°C

Applications

The Gibitre Thermoregulated Block accelerates aging of elastomeric materials in air or liquids up to 250 °C, enabling laboratory measurement to ISO 188, ISO 1817, ASTM D865 and ASTM D471.

Four independent stations allow parallel testing of different materials, reducing cycle time and enabling direct comparison.

Temperature is regulated by a PT100 probe with PID control, integrated timer and automatic heater shutoff for stable, repeatable aging.

A thermally insulated stainless-steel housing and an aluminum block with calibrated wells for glass tubes, plus an over-temperature safety switch, ensure safety and long-term reliability.

An external rack simplifies sample preparation and handling; accessories include 38 mm × 300 mm glass test tubes and water-cooled reflux condensers for liquid aging.

CE-marked, the Gibitre Thermoregulated Block is a robust addition to laboratory testing tools for elastomer measurement, delivering consistent, standards-compliant results.
Why Choose Gibitre Block Oven ?

Overview 

Thermal regulated Block for the performance of aging tests in air and in liquids of elastomeric materials at temperatures up to 250°C conforming to ISO 188, 1817 ASTM D 471 and 865 Standards.
Aging tests are typically carried out to measure the variation of characteristics of an article before and after the aging process. The characteristics that are most frequently measured before and after aging are:
• Variation of mechanical characteristics (loading, lengthening, tearing)
• Variation of hardness
• Percentage variation of mass and volume.
Gibitre, in addition to providing this tool to perform accelerated aging in air or in liquid, also provides the tools to measure changes in the properties of the article and to produce the related reports.

Instruments Characteristics  

The instrument is fitted with:
Aluminium block contained in a stainless steel housing with thermal insulation with 4 calibrated holes designed for the insertion of 4 glass test tubes
Heating resistance
PT 100 thermal probe for temperature measurement
PID thermoregulator
Timer for the set of the heating time with automatic switch off of the heater at the end of the set time

block oven for aging: detail of glass tube housing holes for the block oven instrument
detail of glass tube housing holes for the block oven instrument

Timer for Auto-Stop 

The instrument is equipped with a timer that can be set between 0 and 99 hours and 59 minutes. The instrument automatically stops at the end of the set test time.
The Timer allows you to activate aging cycles by ending the test automatically in the absence of the operator.

block oven for aging: detail of the timers and temperature controller of the block oven instrument
detail of the timers and temperature controller of the block oven instrument
block oven for aging: block-oven-for-aging: detail of the instrument control panel with temperature controller, timer, and control buttons.
 
Test Tubes

Glass Tubes for samples. 

4 glass tubes with a diameter of 38 mm and a length of 300 mm can be inserted into the instrument.
The specimens can be inserted into the glass tubes and locked using the fasteners provided.
Fixing devices allow the specimens to be placed in order to avoid contact with the glass tube walls.

block oven for aging: Block Oven. Detail of a test tube with samples inserted and a vapor condensation column. block oven for aging: Block Oven. Detail of a test tube with samples inserted and a vapor condensation column. block oven for aging: example of preparing specimens for aging block oven for aging: kit for mounting specimens on block oven stand

Glass Tubes for test according to ASTM D865 

The glass tubes are closed in the upper part with PTFE plugs provided with holes for the insertion of the glass pipes requested for the aging test in hot air according to ASTM D865

block oven for aging: Hot air aging test tubes according to ASTM D865 standard block oven for aging: Hot air aging test tubes according to ASTM D865 standard block oven for aging: block-oven-for-aging. Schematic diagram of tube placement for hot-air aging tests according to ASTM D865.

Water-cooled reflux condenser 

For aging tests in volatile liquids it is necessary to use condensation columns connected to a water supply. The condensation columns allow to condense the volatile part of the test liquid and make it fall back into the tube. In this way, the amount and formulation of the liquid in the glasses will remain unchanged.
A condensation column can be applied to each test tube.

block oven for aging: liquid cooling columns for vapor recovery for block oven
liquid cooling columns for vapor recovery for block oven
block oven for aging: block-oven-for-aging: example of glass tube with inserted specimens.
Construction & Calibration

Removable Side Supports 

Together with the instrument are supplied two side supports for housing the glass tubes not in use. The supports can be removed to reduce the overall dimensions of the instrument.

block oven for aging: support for positioning glass tubes in preparation for block oven block oven for aging: support for positioning glass tubes in preparation for block oven block oven for aging: block-oven-for-aging. Side view of the instrument without tube holder mounted.

Safety Devices 

• Safety switch to prevent overheating
• Safety Push-button
• CE Labelling

block oven for aging: Safety First
Safety First

Standard Calibration service for a Block Oven 

The calibration is performed with reference to the requirements of ISO 1817 standard.
The service includes:
• Ordinary maintenance of the instrument
• Calibration of the temperature inside the testing tubes (at 70°C, 150°C, 200°C, 250°C).
• Issue and e-mail shipment of the Calibration Certificate with traceability to primary standards.

Sample Calibration Report
block oven for aging: Gibitre Calibration: full conformity with Standards
Gibitre Calibration: full conformity with Standards
block oven for aging: example of block oven instrument calibration report
Production

Development and production 

The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.

block oven for aging: Proudly made in Italy
Proudly made in Italy

Technical specification

Reference Standards
Standards the instrument complies with:  VDA 675-301; ISO 12046; ASTM D1056; ISO 6916-1; ISO 6916-2; AS_NZS 4179; ISO 175; ASTM D543; ISO 188; ISO 1817; ASTM D471; ASTM D865; EN 681-1;  

Testing Configuration

Test stations  4 glass tubes with a diameter of 38 mm and a length of 300 mm. Each tube can hold up to 6 samples (ISO 37 S2 type).  Condensation Columns  A condensation column cooled with running water can be applied to each test tube to prevent evaporation of the test liquid.  Heating system  The thermal resistance surrounding the round-shaped aluminium block ensures uniform heating of the system  Temperature control range  From room temperature to 250°C (Resolution 1 °C)  Timer for set of test time  Timer with hour and minute settings and automatic heating shut-off at the end of the set time. Set time: from 1 min to 700,000 h 

Safety Devices

Safety devices  Safety Pushbutton.
safety thermostat for over-heating 
Labelling  CE Labelling 

Calibration

Calibration  Calibration Report conforming to ISO 1817 with traceability to primary standards 

Technical specifications

Power supply  220 VAC ±10%, 50 Hz ±3, 10A, single phase - 110 VAC ±10%, 60 Hz ±3 on request.  Electrical power  1.5 kW  Dimensions  Instrument only: 400 x 420 x 360 mm
With test tubes holders: 490 x 420 x 360 mm
And with reflux condenser mounted: 490 x 420 x 860 mm 
Weight  24 Kg 

FAQ

References
Gibitre Block Oven
is currently installed in
19 countries
Request the List of top References
Download
Brief product leaflet
General catalogue mail request

Calibration certificate
example
CE certificate
example
Density Check - Drive
Vedi anche: Density-Check electronic densimeter. Full view of the instrument.
See Also   >
Tensor Check Profile - PC
Vedi anche: Tensor-Check dynamometer. Full view of the instrument.
See Also   >
Manual Digital Hardness Check - Drive
Vedi anche: Manual Hardness Check hardness tester in Drive version. View of the instrument mounted on the stand.
See Also   >
News
Call to action
Ask for quotation
a guided way to ask
for a quotation
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
We welcome your calls Monday through Friday from 8:30 a.m. to 5:30 p.m. in your local time zone.
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Gibitre Instruments S.r.l., Via dell'industria 73, 24126 Bergamo Italia, pec@gibitre-instruments.it P. IVA: IT02827900164 CCIAA REA Bergamo: 326486 | ©2018 - 2026 Gibitre Instruments
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.