Laboratory Press
Laboratory press for the compression moulding of plates and specimens for laboratory tests


Standards the instrument complies with:   
ASTM D3182;   ISO 293;   ISO 2393;   ISO 6916-1;   ISO 6916-2;   UNI 5572;    

Overview 
The laboratory press is an important tool for the preparing of samples with reproducible characteristics.
Uniform temperature distribution over the platen Surface and mechanical solidity to ensure constant thickness of the sample and consistent closure force are basic elements to ensure this result.


Key Features 
• Mechanical structure with 4 columns (with 60 mm diameter) and sliding platen driven by self-lubricating bushings
• Hydraulic system with 25 tons closure force
• 250x250 mm chrome plated steel platens with 40 mm thickness
• Specifically designed flat heating elements to ensure uniform temperature distribution over the platen surface
• Closed moulding area for easy fume aspiration
• Protection doors with safety lock
• CE Labelling


Automatic Press Control 
The PLC controller for the press is provided with a user-friendly Touch Screen Display and permits the free definition of the moulding cycle by setting:
• The displacements of the moving platen of the press,
• The thermal cycle (different temperatures of the platens and thermal gradients can be set within a moulding cycle)
• The pressure cycle (with the force control option installed).
Three Moulding cycles can be stored. Each cycle includes 24 moulding steps (including displacements, temperatures setups and pressure setups)




Cooling system 
The cooling of the press platens during the molding cycle is necessary for the molding of thermoplastic materials because the material must be cooled to the solidification temperature before opening the mold.

The Gibitre press can be equipped with cooling device that allows the cooling of the platens at controlled speed.


Closure Force Control 
The Digital pressure regulation system is designed for applications that require an accurate control of closure force.
A specific 2-stages hydraulic circuit, which includes proportional regulation valves and continuous fine regulation pumping system, has been designed to ensure accurate pressure control.
The results is a smooth and consistent force control which permit to set the closure force between 10 kN and 250 kN with 10 N set force regulation steps with regulation oscillations lower than 1000 N.
The control of the closing force is performed using the Automatic Press Control that must be installed in combination with the Closure Force Control option.
The Automatic Press Control device permits to set multiple pressure regulation steps within the moulding cycle.


Moulds 
Moulds for producing plates and different types of samples according to international standards are available. Fixing rails with sliding system permit easily handling of the moulds. Mould produced upon customer design and company logo engraving are available on request.



Gibitre Press Logger 
The Automatic Press Control device is fitted with a USB port which permits the connection to a Pc. The Gibitre Press Logger program permits the continuous recording of the press conditions (temperature, pressure, moving platen position, cycle step). Both graphical and numerical recording is provided with automatic generation of daily storage files. The program is compatible with Windows 7 and 8 and 10 (64 bits).

Standard Calibration service for Laboratory Press 
Maintenance and Calibration service for your Laboratory Press.
The service includes:
• Ordinaly maintenance of the instrument
• Calibration of the temperature of the platens. The temperature is measured, with the plates closed, in 9 different points of the platens and at 3 different temperatures (140°C, 170°C, 200°C).
• Calibration of the closure Force (50, 100, 150, 250 kN)
• Issue and e-mail shipment of the Calibration Certificate with traceability to primary standards.


Safety devices 
• Safety protection doors fitted with safety switch.
• Safety Push-button
• CE labelling




Development and production 
The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.



Instrument Characteristics 
 
Max useable platen surface 
250 mm x 250 mm 
Max closure force 
25 Tons 
Max platen stroke 
200 mm 
Temperatures 
Up to 250°C (300°C optional).
0.1°C Resolution.
Maximum Temperature difference (200x200mm area):2°C 
Cooling System (Option) 
Cooling of the platens with controlled cooling gradient. The cooling is controlled using the Automatic Press control PLC device 
Closure force Control(option) 
Continuous control of the closing force with regulation between 10 and 250 kN with 10N regulation steps. Max. regulation error: 1 kN. 
Press control device 
 
Touch Screen PLC controller 
PLC with touch-screen display. Permits to: • set displacements of the moving plate • set the temperatures • activate the cooling and cooling rate (with cooling option) • set closure force (with force regulation option) 
Safety Devices 
 
Safety Devices 
• Safety Pushbutton.
• Doors with safety switch 
Labelling 
CE Labelling 
Calibration 
 
Calibration Report 
Calibration report with traceability to primary standards in conformity with the Calibration requirements specified in ISO 2393 standard 


Calibrated parameters 
The certificate includes the calibration of:
- temperature of the platens. The measure is performed in 9 different points of the platens and at 3 different temperatures (140°C, 170°C, 200°C).
- Closure force (with Pressure control option) 
Construction Characteristics 
 
Platen temperature control 
- Electrical heating.
- Independent temperature control of the plates by means of PID controllers 
Power supply 
380 VAC ±10%,50 Hz ±3, 10 A,three-phase -Other on request 
Electrical power 
6 KW 
Instrument dimensions (with mounted side drawer) 
(Width x Depth x Height) 1200 x 950 x 1800 mm 
Instrument dimensions (without side drawer) 
(Width x Depth x Height) 650 x 950 x 1800 mm 
Weight 
520 Kg 
Cooling System 
 
Cooling System 
The cooling is perform with the connection too a water source (or a chiller). The control of the cooling and of the cooling rate are controlled by the PLC controller. 
Connection to cooling liquid 
The water supplied to the Press must be demineralized.
The fittings for the inlet water is 1/4" 
Insulated tank for cooling water (optional) 
The hot water, which exits from the cooling circuit, must be cooled before being discharged. The insulated tank permits to store and cool the water before the discharge 
Water consumption 
The cooling of the platens of the press, starting from 250°C down to 70°C requires approxiametely 30 liters of water. The quantity changes depending from the temperature of the water used. 
Software 
 
Gibitre Press Logger 
Software compatible with Windows 7, 8 and 10 for continuous recording of the press conditions (temperature, pressure, moving platen position, cycle step).
The software is connected to the press with USB cable 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Gibitre Instruments

Laboratory Press

Laboratory press, with 250x250 mm platens and 25 T closure force, for the compression moulding of plates and specimens.




 
Overview 
The laboratory press is an important tool for the preparing of samples with reproducible characteristics.
Uniform temperature distribution over the platen Surface and mechanical solidity to ensure constant thickness of the sample and consistent closure force are basic elements to ensure this result.

Key Features 
• Mechanical structure with 4 columns (with 60 mm diameter) and sliding platen driven by self-lubricating bushings
• Hydraulic system with 25 tons closure force
• 250x250 mm chrome plated steel platens with 40 mm thickness
• Specifically designed flat heating elements to ensure uniform temperature distribution over the platen surface
• Closed moulding area for easy fume aspiration
• Protection doors with safety lock
• CE Labelling
Automatic Press Control 
The PLC controller for the press is provided with a user-friendly Touch Screen Display and permits the free definition of the moulding cycle by setting:
• The displacements of the moving platen of the press,
• The thermal cycle (different temperatures of the platens and thermal gradients can be set within a moulding cycle)
• The pressure cycle (with the force control option installed).
Three Moulding cycles can be stored. Each cycle includes 24 moulding steps (including displacements, temperatures setups and pressure setups)

 
Cooling system 
The cooling of the press platens during the molding cycle is necessary for the molding of thermoplastic materials because the material must be cooled to the solidification temperature before opening the mold.

The Gibitre press can be equipped with cooling device that allows the cooling of the platens at controlled speed.

Closure Force Control 
The Digital pressure regulation system is designed for applications that require an accurate control of closure force.
A specific 2-stages hydraulic circuit, which includes proportional regulation valves and continuous fine regulation pumping system, has been designed to ensure accurate pressure control.
The results is a smooth and consistent force control which permit to set the closure force between 10 kN and 250 kN with 10 N set force regulation steps with regulation oscillations lower than 1000 N.
The control of the closing force is performed using the Automatic Press Control that must be installed in combination with the Closure Force Control option.
The Automatic Press Control device permits to set multiple pressure regulation steps within the moulding cycle.

Moulds 
Moulds for producing plates and different types of samples according to international standards are available. Fixing rails with sliding system permit easily handling of the moulds. Mould produced upon customer design and company logo engraving are available on request.

Read more about Gibitre Moulds
Gibitre Press Logger 
The Automatic Press Control device is fitted with a USB port which permits the connection to a Pc. The Gibitre Press Logger program permits the continuous recording of the press conditions (temperature, pressure, moving platen position, cycle step). Both graphical and numerical recording is provided with automatic generation of daily storage files. The program is compatible with Windows 7 and 8 and 10 (64 bits).

Standard Calibration service for Laboratory Press 
Maintenance and Calibration service for your Laboratory Press.
The service includes:
• Ordinaly maintenance of the instrument
• Calibration of the temperature of the platens. The temperature is measured, with the plates closed, in 9 different points of the platens and at 3 different temperatures (140°C, 170°C, 200°C).
• Calibration of the closure Force (50, 100, 150, 250 kN)
• Issue and e-mail shipment of the Calibration Certificate with traceability to primary standards.

Request a sample Calibration Report

Gibitre Calibration: full conformity with Standards
Safety devices 
• Safety protection doors fitted with safety switch.
• Safety Push-button
• CE labelling

Safety First
Development and production 
The instrument is totally developed and produced in the plant of Gibitre Instruments in Italy.
All the mechanical parts are produced in the company workshop using modern CNC machines.
Components and sensors from well-known brands are selected in order to ensure the maximum reliability in the measures
Internal trained personnel takes care of all the production stages: assembly, start-up, calibration, packing, shipment and installation.

Proudly made in Italy
 
Technical specifications
Reference Standards
Standards the instrument complies with:  ISO 6916-2; ISO 293; ISO 2393; ASTM D3182; ISO 6916-1; UNI 5572;  
Instrument Characteristics
Max useable platen surface  250 mm x 250 mm  Max closure force  25 Tons  Max platen stroke  200 mm  Temperatures  Up to 250°C (300°C optional).
0.1°C Resolution.
Maximum Temperature difference (200x200mm area):2°C 
Cooling System (Option)  Cooling of the platens with controlled cooling gradient. The cooling is controlled using the Automatic Press control PLC device  Closure force Control(option)  Continuous control of the closing force with regulation between 10 and 250 kN with 10N regulation steps. Max. regulation error: 1 kN. 
Press control device
Touch Screen PLC controller  PLC with touch-screen display. Permits to: • set displacements of the moving plate • set the temperatures • activate the cooling and cooling rate (with cooling option) • set closure force (with force regulation option) 
Safety Devices
Safety Devices  • Safety Pushbutton.
• Doors with safety switch 
Labelling  CE Labelling 
Calibration
Calibration Report  Calibration report with traceability to primary standards in conformity with the Calibration requirements specified in ISO 2393 standard  Calibrated parameters  The certificate includes the calibration of:
- temperature of the platens. The measure is performed in 9 different points of the platens and at 3 different temperatures (140°C, 170°C, 200°C).
- Closure force (with Pressure control option) 
Construction Characteristics
Platen temperature control  - Electrical heating.
- Independent temperature control of the plates by means of PID controllers 
Power supply  380 VAC ±10%,50 Hz ±3, 10 A,three-phase -Other on request  Electrical power  6 KW  Instrument dimensions (with mounted side drawer)  (Width x Depth x Height) 1200 x 950 x 1800 mm  Instrument dimensions (without side drawer)  (Width x Depth x Height) 650 x 950 x 1800 mm  Weight  520 Kg 
Cooling System
Cooling System  The cooling is perform with the connection too a water source (or a chiller). The control of the cooling and of the cooling rate are controlled by the PLC controller.  Connection to cooling liquid  The water supplied to the Press must be demineralized.
The fittings for the inlet water is 1/4" 
Insulated tank for cooling water (optional)  The hot water, which exits from the cooling circuit, must be cooled before being discharged. The insulated tank permits to store and cool the water before the discharge  Water consumption  The cooling of the platens of the press, starting from 250°C down to 70°C requires approxiametely 30 liters of water. The quantity changes depending from the temperature of the water used. 
Software
Gibitre Press Logger  Software compatible with Windows 7, 8 and 10 for continuous recording of the press conditions (temperature, pressure, moving platen position, cycle step).
The software is connected to the press with USB cable 
Download
Product leaflet

General catalogue

Calibration certificate
example
CE certificate
example
 

Faq

?

?

 
Ask for quotation

Ask for quotation
Mail

Mail
Mail
Phone

Phone
Phone
Local agent


Local agent
FAQ
do you need more information or a quotation?
use the buttons at the bottom of the page.
Cookie policy
Questo sito utilizza i cookies (dati permanenti registrati sul tuo PC) per:
- ricordare la lingua scelta
- ricordare i prodotti preferiti
- suggerire prodotti in funzione delle pagine più visitate
- mantenere aperta la sessione (nella sole aree riservata)

Cliccando su "accetta" autorizzate l'uso dei cookies.

Accetto / Accept

This site uses cookies (permanent data on your PC) for:
- remembering the choosed language
- remembering your favorite products
- suggest other products based upon the most viewed pages
- keep the navigation session open (only in the reserved area)

By ckicking on "accept" you authorize the use of cookies.